Overview
AVE.N series fast opening and closing gas solenoid valve.Used in the field of safe transportation control to provide opening and closing or cutting off gas supply.
The solenoid valve is suitable for gas media, such as natural gas, methane, liquefied petroleum gas and other gases to do two-position on-off power exchange for heating and combustion medium pipelines.
It is widely used in gas heat setting of metallurgical industry, textile industry, printing industry, kiln heating of glass and light bulb industry and automatic control system of gas heating in other industries
Features
It has a wide range of models and specifications and is suitable for a variety of gas media.
Open time and close time: AVE.N series less than 1 second.
The coil connection box has a power indicator, which can directly observe the power on and off state of the valve.
It can work normally under vacuum, negative pressure and zero pressure, and the highest working pressure can reach 200mabr.
It has high safety,reliability, adaptability and economy.
Precautions for installation and use of AVE N32 gas solenoid valve
The horizontal pipe section with less vibration should be selected during installation. 90 degrees installation is allowed below DN50, and horizontal installation is only allowed on DN65.
The parameters on the solenoid valve nameplate should be consistent with the actual use requirements.
The arrowhead on the solenoid valve body should be consistent with the media flow direction.
Please clean the pipe thoroughly before installation to avoid the failure of solenoid valve caused by foreign body damage diaphragm.
Effective protection should be done if installed outdoors and in harsh environment.It is recommended to install a filter AF upstream of the solenoid valve to protect the solenoid valve from foreign bodies, dust. etc.
It is suggested that a manual cut-off valve should be installed upstream of the solenoid valve. When the solenoid valve fails, it can be isolated in time and is convenient for maintenance.If the opening and closing of the valve fails in use, you can check whether the coil is powered off, whether the power supply and medium pressure are normal.
When the solenoid valve is not installed temporarily, it can be stored in the room where the ambient temperature is 0-40 ℃ C and the relative humidity is less than 80%. Open-air storage is not allowed.
Ensure that all functions of the system comply with valve specifications (gas type, working pressure, flow rate,ambient temperature, voltage, etc.).
Maintenance cycle once a year, and increase the number of maintenance as appropriate, such as corrosive gases.
Technical Parameters | |
Opened: | AVE. N series less than 1 second |
Working medium: | Natural gas, methane, liquefied petroleum gas, etc.. |
Working temperature: | -15°C-60'C |
Maximum operating frequency: | AVE. N series 20 beats per minute |
Maximum working pressure: | DN15-50 200mbar |
Rated voltage: | 50/60Hz, 230Vac, coil class F,360°rotation, 100% long-tem continuous operation |
Protection class: | IP54, do not install in the open air |
Sealing material: | Nitrile rubber |
Body material: | Valve aluminum alloy, AISl302 steel spring |
Coil temperature: | 65'C ( ambient temperature 20°C) |